iVS6-5R0-5R0-61-A - Astec iVS6-5R0-5R0-61-A Power Supply- iVS Series 3210 Watts Simple Type:...
Request Quote
For Price
- Part Number:
- iVS6-5R0-5R0-61-A
- Model Number:
- iVS6-5R0-5R0-61-A
- Make:
- AS
- Lead Time:
- Available
- Qty In Stock:
- Available
Astec iVS6-5R0-5R0-61-A Power Supply- iVS Series 3210 Watts Simple Type: Power Supply
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- Configurable inhibit/enable
- Configurable input and output OK signals and indicators
- Configurable output UP/DOWN sequencing
- Field upgradeable firmware
- Full medical EN60601 approval
- High power density (12 W/cu-in)
- I2C monitor of voltage, current,and temperature
- Increased power density to 150%
- Industrial temp range (-40 ºC to 70 ºC)
- Intelligent fan (speed control/fault status)
- Intelligent I2C control
- Optional conformal coating
- Optional extended hold-up module (SEMI F47 compliance)
- Programmable voltage, current limit, inhibit/enable through I2C
- RoHS compliant
- uP controlled PFC input with active Inrush protection
- Uses standard iMP modules
- Voltage adjustment on all outputs(manual or I2C)
Specifications
- AC OK: >5ms early warning minutes before outputs lose regulation Full cycle
- Adjustment range: ± 10% minimum all outputs (manual)(full module adjustment range using I2C)
- Dynamic response: < 2% or 100 mV, with 25% load step
- Efficiency: Up to 85% @ full case load
- EMI filter: CISPR 22/EN55022 Level “B”
- Factory set point accuracy: 1%
- Frequency: 47 - 440 Hz
- Global inhibit / enable: TTL, Logic “1” and Logic “0”; configurable
- Harmonic distortion: Meets EN61000-3-2
- Holdover storage: 10 ms minimum (independent of input Vac) additional 20mSEC
- I2C output program accuracy: ± 5%
- Input Range: 170 - 264 Vac 3Ø
- Inrush Current: 40 A peak maximum (soft start)
- Isolation: Meets EN60950 and EN60601
- Leakage Current: 500 µA max. @ 240 Vac; 47-63 Hz
- Margining: ± 4 - 6% nominal analog (single output module only)
- Overall regulation: 0.4% or 20 mV max. (1500 W modules 1% max.)
- Pk-Pk: 1.0% or 50 mV, whichever is greater Bandwidth limited to 20 MHz
- Power Factor: 0.99 typ. meets EN61000-3-2
- Radiated EMI: CISPR 22/EN55022 Level “B”
- Recovery time: To within 1% in < 300 µsec
- Ripple: RMS: 0.1% or 10 mV, whichever is greater
- Turn-On Time: AC on 1.5 sec typical, inhibit/enable 150ms typical Programmable;
Applications
- None Available
Aliases
- None Available